Product Description
When an assay calls for temperatures just below room temperature, this OHAUS incubating cooling shaker holds samples anywhere from 10°C below ambient up to 65°C while shaking microplates or modular blocks at up to 1200 rpm. Independent LED displays show temperature, speed and time at a glance, so setup and monitoring take seconds.
This listing is for OHAUS item number 30391945: Incubating Cooling Orbital Shaker ISICMBCDG, 10°C Below Ambient to 65°C, 100-1200 rpm, 120 V. A triple eccentric drive with brushless DC motor gives stable 3 mm orbital motion under microprocessor control. The cast aluminum housing and polycarbonate lid are spill resistant, and overload protection, a caution-hot indicator and TUV safety certification help protect both users and samples. LIGHT LABS ships genuine OHAUS products and can help you match accessories and parts to your instrument.
Key Features
- Heating and Cooling – controls from 10°C below ambient to 65°C with ±0.5°C uniformity at 37°C
- Microplate and Block Capacity – holds 2 microplates or 2 modular blocks
- Triple Eccentric Drive – brushless DC motor delivers smooth 3 mm orbital motion from 100 to 1200 rpm
- Independent LED Displays – temperature, speed and time visible simultaneously
- Long Run Timer – programmable from 1 second to 9,600 minutes
- Built-In Safety – spill-resistant design, overload protection and caution-hot indicator
Specifications
| Item Number | 30391945 |
| Brand | OHAUS |
| Description | Incubating Cooling Orbital Shaker ISICMBCDG, 10°C Below Ambient to 65°C, 100-1200 rpm, 120 V |
| Motion | Orbital, 3 mm |
| Capacity | 2 Microplates or 2 Modular Blocks |
| Temp. Range | 10°C below Ambient – 65°C |
| Speed Range | 100 rpm – 1200 rpm |
| Control | Digital |
| Speed Range - Microplates | 100 to 1200 rpm |
| Speed Range - Modular Blocks | 100 to 600 rpm |
| Calibration | Temperature calibration |
| Dimensions | 17.9 in x 10.5 in x 11 in (45.5 cm x 26.7 cm x 27.9 cm) (LxHxW) |
| Drive System | Triple Eccentric;Brushless DC Motor |
| Net Weight | 29.5 lb (13.4 kg) |
| Orbit | 0.1 in (3 mm) |
| Power | 120V, 2A, 50/60Hz |
| Power Consumption | 200 W |
| Safety Certification | TUV |
| Speed Accuracy | ±2% |
| Timer | 1 s - 9,600 min |
| Uniformity | ± 0.5°C at 37°C |
| Working Environment | 41°F – 104°F, 80% RH, Non-condensing (5°C – 40°C, 80% RH, Non-condensing) |
Applications
- ELISA assays
- Immunoassays
- Hybridizations
- Bacterial and yeast cultures
- Enzyme reactions
- PCR sample preparation