Product Description
LIGHT LABS is proud to offer the Sorenson BioScience 200 µL LTS-Compatible Low Retention Barrier Pipette Tip (Cat # 87950T) — a LIGHT LABS exclusive low retention version of the Sorenson 87950, combining LTS compatibility for Rainin LiteTouch™ pipettors with low retention surface technology for reduced sample adsorption and maximum sample recovery in the 200 µL tip format. The 87950T is available exclusively through LIGHT LABS — making it a unique offering for Rainin LiteTouch™ pipettor users who require low retention performance in an LTS-compatible barrier tip at the 200 µL volume.
The LTS (LiteTouch System) design of the 87950T is specifically engineered with the precise geometry required to seal effortlessly onto Rainin LiteTouch™ pipettor nozzles — requiring significantly less insertion and ejection force than universal tips. This ergonomic advantage is especially impactful at the 200 µL scale, where 200 µL LTS tips are among the most frequently used tip sizes in routine laboratory workflows and where repetitive pipetting fatigue from conventional universal tips accumulates rapidly. The 87950T is additionally compatible with the Sequence BioTech 96-channel Benchtop Pipettor — broadening its utility to high-throughput automated 96-well pipetting applications.
The inert polyethylene (PE) barrier filter prevents aerosols and liquids from entering and contaminating the pipettor — without trapping liquid or shedding particulates into the sample. Graduation lines provide quick accuracy checks during pipetting. The fine point delivery system ensures crisp, precise sample dispensing. The low retention surface treatment of the 87950T minimizes non-specific adsorption of DNA, RNA, proteins, enzymes, and other precious biological samples to the tip wall — a critical advantage for high-value or limiting samples in the 200 µL volume range. MultiRack format: 96 tips per rack, 10 racks per pack, 5 packs per case (4,800 tips total). LIGHT LABS is your trusted source for Sorenson BioScience pipette tips.
KEY FEATURES
- LTS (LiteTouch System) compatible — specifically engineered for Rainin LiteTouch™ pipettors; less insertion and ejection force than universal tips; NOT a universal-fit tip
- Compatible with Sequence BioTech 96-channel Benchtop Pipettor — extends compatibility to automated high-throughput 96-well pipetting applications
- Less insertion and ejection force than universal tips — reduced hand and wrist fatigue during repetitive high-throughput 200 µL pipetting workflows
- Low retention surface treatment — minimizes non-specific adsorption of DNA, RNA, proteins, enzymes, and precious biological samples; exclusive LIGHT LABS variant (87950T)
- Inert polyethylene (PE) filter barrier — prevents aerosol and liquid from entering pipettor; will NOT trap liquid or contaminate samples
- Graduation lines — quick accuracy checks during pipetting
- Fine point delivery system — crisp, precise sample dispensing
- 200 µL format — most widely used LTS-compatible tip size for routine laboratory workflows
- MultiRack format — 96 tips per refillable, stackable rack; 10 racks per pack; 5 packs per case
- Sterile — gamma irradiated
- Certified RNase-free, DNase-free, and nonpyrogenic
- Made from 100% virgin polypropylene (PP)
- Exclusive low retention variant available only through LIGHT LABS
SPECIFICATIONS
| Attribute | Detail |
|---|---|
| Catalog Number | 87950T |
| Brand | Sorenson BioScience |
| Product Name | 200 µL LTS-Compatible Low Retention Barrier Tip — MultiRack |
| Volume | 200 µL |
| Pipettor Compatibility | Rainin LiteTouch™ (LTS) pipettors; Sequence BioTech 96-channel Benchtop Pipettor |
| Barrier Type | Inert polyethylene (PE) filter — liquid trap-free |
| Surface Treatment | Low Retention |
| Graduation Lines | Yes |
| Delivery | Fine point |
| Material | 100% virgin polypropylene (PP) |
| Color | Clear |
| Sterility | Sterile (gamma irradiated) |
| Certifications | RNase-free, DNase-free, nonpyrogenic |
| Rack Format | MultiRack |
| Packaging | 96 tips/rack; 10 racks/pack; 5 packs/case |
| Quantity | 4,800 tips/case |
| Exclusive Format | Low retention (87950T) — LIGHT LABS exclusive |
LTS-COMPATIBLE vs. UNIVERSAL FIT — CRITICAL DISTINCTION
| Feature | LTS-Compatible (87950T) | Universal Fit (77280T / 87270T) |
|---|---|---|
| Pipettor Compatibility | Rainin LiteTouch™ + Sequence BioTech 96-ch | All standard pipettors |
| Insertion Force | Significantly less | Standard |
| Ejection Force | Significantly less | Standard |
| Seal Quality | Optimized for LTS nozzle | Universal seal |
| Best For | Rainin LiteTouch™ users | All other pipettor brands |
APPLICATIONS
- High-throughput 200 µL liquid handling with Rainin LiteTouch™ single or multichannel pipettors
- Automated 96-well pipetting with Sequence BioTech 96-channel Benchtop Pipettor
- DNA, RNA, and protein pipetting requiring low retention surface for maximum sample recovery
- PCR and molecular biology requiring RNase-/DNase-free certified tips in LTS format
- Enzyme and antibody handling requiring low retention and barrier protection
- High-value or limiting sample handling requiring minimum sample loss from tip wall adsorption
- Any Rainin LiteTouch™ pipettor application requiring 200 µL LTS-compatible tips with barrier and low retention