Product Description
The Zymo Research RNA Clean & Concentrator™-5 R1014 is a 200-preparation RNA cleanup and concentration kit — providing a simple and reliable method for the rapid preparation of high-quality, RT-PCR-ready, DNA-free RNA. This simple procedure is based on the use of a unique single-buffer system and Zymo-Spin column technology that allows for selective recovery of total RNA (>17 nt), large RNAs (>200 nt), and/or small RNAs (17–200 nt). The procedure is easy: Add binding buffer and ethanol to your sample, then bind, wash and elute ultra pure RNA. The RNA can be eluted from the Zymo-Spin IC Column in as little as ≥6 µl of RNase-free water. The highly-concentrated, purified RNA is suitable for all subsequent analyses and molecular manipulations. DNase I Set included. 200 preparations. Catalog # R1014. The 50-preparation version is available as R1013.
R1014 vs. R1013 — Choosing the Right Kit Size: The R1014 and R1013 are identical RNA Clean & Concentrator™-5 kits in every way — the number of preparations and reagent volumes are the sole differences:
| R1014 | R1013 | |
|---|---|---|
| Preparations | 200 | 50 |
| DNase I Set | ✅ Included | ✅ Included |
| RNA Binding Buffer | 100mL | 25mL |
| RNA Prep Buffer | 100mL | 25mL |
| RNA Wash Buffer | 48mL | 12mL |
| Zymo-Spin™ IC Columns | 200 | 50 |
| Collection Tubes | 400 | 100 |
| Best For | High-volume labs, core facilities, routine large-scale RNA cleanup | Standard labs, evaluation, low-throughput |
The R1014 is the preferred choice for high-throughput RNA biology labs, core genomics facilities, and any environment where RNA cleanup is a routine, high-frequency workflow step. At 200 preparations, the R1014 reduces kit reordering frequency, provides a lower per-prep reagent cost, and minimizes workflow interruption from kit changeovers.
R1014 vs. R1013 vs. R1015 vs. R1016 — Understanding the Complete Family:
| R1013 | R1014 | R1015 | R1016 | |
|---|---|---|---|---|
| Preparations | 50 | 200 | 50 | 200 |
| DNase I Set | ✅ Included | ✅ Included | ❌ Not included | ❌ Not included |
| Best For | DNA-free RNA — standard | DNA-free RNA — high volume | RNA cleanup only | RNA cleanup — high volume |
The R1014 is the correct choice for high-volume labs that routinely require DNA-free RNA — the included DNase I Set allows in-column DNase digestion to eliminate genomic DNA contamination as an integrated single-workflow step across all 200 preparations.
5-Minute RNA Cleanup — Ultra-Pure RNA in Minutes at Scale Quick, 5-minute recovery of ultra-pure RNA (≥17 nt) from enzymatic reactions, aqueous phase (following TRIzol® extraction), and other sources. The 5-minute preparation time is preserved across the full 200-preparation R1014 kit — allowing high-throughput labs to process large batches of samples rapidly without sacrificing cleanup quality or RNA purity. For core facilities and labs running 10, 20, or more samples simultaneously, the consistent 5-minute protocol allows accurate throughput scheduling and capacity planning across the full kit lifetime.
DNase I Set Included — In-Column DNA Elimination Across All 200 Preps The R1014 is supplied with the DNase I Set (E1010) — enabling optional in-column DNase digestion to eliminate genomic DNA contamination directly on the column during the cleanup workflow across all 200 preparations. The in-column DNase treatment is performed directly on the spin column matrix between the RNA binding and wash steps — adding a single additional incubation step without requiring a separate tube, additional centrifugation steps, or heat inactivation that could affect RNA integrity.
Selective RNA Recovery — Total RNA, Large RNA, or Small RNA at High Throughput A distinctive feature of the RNA Clean & Concentrator™-5 is its ability to selectively recover different RNA size classes from the same sample — available across all 200 preparations of the R1014:
- Total RNA (>17 nt) — standard protocol recovers all RNA species including mRNA, rRNA, tRNA, and small RNAs
- Large RNA only (>200 nt) — modified protocol selectively retains mRNA and rRNA while small RNAs pass through
- Small RNA only (17–200 nt) — save the column flow-through from the large RNA protocol to collect miRNA, siRNA, and other small RNA species
≥6µL Minimum Elution — Highly Concentrated RNA in Minimal Volume The RNA can be eluted from the Zymo-Spin IC Column in as little as ≥6 µl of RNase-free water — producing the most highly concentrated RNA eluate available from a spin column cleanup kit, maintained consistently across all 200 preparations of the R1014.
NGS-Ready RNA — A260/A280 and A260/A230 >1.8 Purity — A260/A280 & A260/A230 >1.8. RNA is ready for Next-Gen Sequencing, RT-qPCR, etc. The consistently high purity of RNA purified with the RNA Clean & Concentrator™-5 meets the purity standards required for next-generation sequencing library preparation — maintained across all 200 preparations in the R1014.
Broad Sample Compatibility — RNA from Any Source Compatible with:
- TRIzol®/chloroform extraction aqueous phase — the most common input for RCC cleanup
- In vitro transcription (IVT) reactions — CRISPR guide RNA, mRNA therapeutics, antisense RNA
- DNase I treated RNA — post-DNase cleanup
- Reverse transcription reactions — cDNA cleanup and concentration
- Enzymatic reactions — removal of enzymes, primers, nucleotides, and salts
- Dilute RNA samples — concentration into small, analysis-ready volumes
- Compatible with ≤0.1% Sarkosyl, ≤0.1% SDS, ≤90% Sucrose, ≤90% Formamide, and ≤2% Formaldehyde
Room Temperature Storage — Complete Kit at Bench Temperature Store all kit components at room temperature. All R1014 components are stored at room temperature — simplifying large-format kit storage in high-throughput lab environments. Reconstituted DNase I is stored as frozen aliquots after preparation.
Complete Kit Contents — R1014 (200 Preps):
| Component | R1014 Quantity | Storage |
|---|---|---|
| RNA Binding Buffer | 100mL | Room temperature |
| RNA Prep Buffer | 100mL | Room temperature |
| RNA Wash Buffer (concentrate) | 48mL | Room temperature |
| DNase/RNase-Free Water | 4mL | Room temperature |
| DNase I Set (E1010) | Included | Room temp (lyophilized); -20°C (reconstituted) |
| Zymo-Spin™ IC Columns | 200 | Room temperature |
| Collection Tubes | 400 | Room temperature |
| Instruction Manual | 1 | — |
Compatible Replacement — Cross-Reference Guide
The Zymo Research RNA Clean & Concentrator™-5 R1014 is a comparable alternative to high-volume RNA cleanup kits from several major manufacturers:
- Qiagen RNeasy MinElute Cleanup Kit (74204) — RNA cleanup and concentration kit
- Thermo Fisher RNA Clean XP (Beckman Coulter A63987) — SPRI bead-based RNA cleanup
- Norgen Biotek RNA Cleanup and Concentration Kit (23600) — RNA cleanup kit
- New England Biolabs Monarch RNA Cleanup Kit (T2030L) — RNA cleanup and concentration
These products may differ in protocol, yield, and performance characteristics. The R1014 is specifically cited in published literature and protocols by catalog number.
Key Features
- Zymo Research RNA Clean & Concentrator™-5 — Catalog # R1014
- 200 preparations with Zymo-Spin™ IC Columns — high-volume format
- DNase I Set (E1010) included — in-column DNA elimination across all 200 preps
- 5-minute cleanup procedure
- Single-buffer system — simple, rapid, reliable
- Selective recovery of total RNA (>17 nt), large RNA (>200 nt), or small RNA (17–200 nt)
- 10µg RNA binding capacity per column
- Minimum elution volume: ≥6µL
- A260/A280 and A260/A230 >1.8 — NGS-ready purity
- Compatible with TRIzol® aqueous phase, IVT products, DNase-treated RNA, enzymatic reactions
- RT-PCR-ready, NGS-ready, hybridization-ready
- Room temperature storage — all kit components
- 1-year kit component integrity guarantee
- Lot-to-lot tested for performance and reliability
- Lowest per-prep cost in the R1013/R1014 DNase-included line
- Smaller pack size available: R1013 (50 preps)
- Without DNase versions: R1015 (50 prep), R1016 (200 prep)
Supported Applications RNA cleanup and concentration following TRIzol®/phenol-chloroform extraction, in vitro transcription (IVT) product cleanup for CRISPR guide RNA, mRNA therapeutics and antisense RNA, post-DNase treatment RNA cleanup, cDNA cleanup following reverse transcription, dilute RNA concentration, small RNA and miRNA cleanup, RNA cleanup prior to NGS library preparation, RT-qPCR sample preparation, microarray hybridization, Northern blotting, RNA size fractionation (large vs. small RNA separation), high-throughput RNA processing in core genomics facilities, and any molecular biology workflow requiring rapid, highly concentrated, DNA-free RNA with NGS-grade purity at high volume.
Technical Specifications
| Specification | Value |
|---|---|
| Catalog # | R1014 |
| Manufacturer | Zymo Research |
| Kit Name | RNA Clean & Concentrator™-5 |
| Preparations | 200 |
| Column Type | Zymo-Spin™ IC |
| DNase I Set | Included (E1010) |
| RNA Binding Capacity | 10µg per column |
| Minimum Elution Volume | ≥6µL |
| RNA Size Recovery | Total RNA ≥17 nt; Large RNA >200 nt; Small RNA 17–200 nt |
| Purity | A260/A280 and A260/A230 >1.8 |
| Preparation Time | ~5 minutes |
| Buffer System | Single RNA Binding Buffer |
| Sample Compatibility | TRIzol® aqueous phase, IVT products, DNase-treated RNA, enzymatic reactions, dilute RNA |
| Chaotropic Compatibility | ≤0.1% Sarkosyl, ≤0.1% SDS, ≤90% Sucrose, ≤90% Formamide, ≤2% Formaldehyde |
| Storage | Room temperature (all components); -20°C (reconstituted DNase I) |
| Kit Integrity Guarantee | 1 year from date of purchase |
| Smaller Pack Size | R1013 (50 preps) |
| Without DNase | R1015 (50 prep), R1016 (200 prep) |