Product Description
The CELLTREAT® 229703 is a complete 500mL sterile vacuum filter system — bottle top filter with 0.45µm PES membrane, 500mL solution bottle, and HDPE screw cap — designed for vacuum filtration of 500mL volumes where particle removal, solution clarification, and pre-filtration are required without a full sterile filtration requirement. New! 500mL Filters feature expanded 90mm diameter membrane to increase flow and reduce clogs for faster filtration. 90mm diameter membrane has 44% more filtration area than previous membrane. The polyethersulfone (PES) membrane provides high flow rate with low protein binding. Complete vacuum filtration systems include a polystyrene bottletop filter and solution bottle with high-density polyethylene screw-on cap. Angled hose barb adapter fits 6-, 9-, and 12-mm ID tubing and prevents filter from tipping. Filter systems are supplied sterile (gamma irradiated); packaged individually. RNase-free, DNase-free, and non-pyrogenic. Shelf life: 36 months. 12 filter systems per case.
⚠️ Important — 0.45µm Does NOT Provide Sterile Filtration The 229703 0.45µm filter is designed for solution clarification and particle removal — not sterile filtration. For sterile filtration of cell culture media and buffers at 500mL scale, the 0.22µm 229707 is the correct product. The 229703 is appropriate for HPLC mobile phase preparation, solution pre-filtration, buffer clarification, and any 500mL application where removal of particles ≥0.45µm is required without a sterility requirement.
229703 vs. 229707 — Choosing the Right Pore Size for 500mL Filtration:
| 229703 | 229707 | |
|---|---|---|
| Volume | 500mL | 500mL |
| Pore Size | 0.45µm | 0.22µm |
| Sterile Filtration | ❌ No — clarification only | ✅ Yes |
| Membrane Dia. | 90mm | 75mm |
| Flow Rate | Higher (larger pore) | Moderate |
| Best For | HPLC prep, pre-filtration, clarification | Sterile media and buffer preparation |
| Case Qty | 12 | 12 |
Expanded 90mm Membrane — 44% More Filtration Area 90mm diameter membrane has 44% more filtration area than previous membrane. The expanded 90mm membrane diameter of the 229703 provides significantly more filtration surface area than the previous-generation membrane — distributing the 500mL particulate load across a wider area, reducing local fouling and clogging, and maintaining higher flow rates throughout the complete filtration volume. The larger membrane is especially valuable when filtering particulate-rich solutions such as crude cell lysates, conditioned media with cell debris, or high-protein solutions that would rapidly foul a smaller membrane.
0.45µm PES Membrane — High Flow Rate with Low Protein Binding Polyethersulfone (PES) membrane is designed for high flow rate with low binding. 0.45µm PES membrane ideal for solution clarification. The 0.45µm pore size presents significantly less hydraulic resistance than a 0.22µm membrane — allowing faster filtration of equivalent volumes under the same vacuum. The inherently hydrophilic and low protein binding PES surface minimizes loss of proteins and biologically active components during filtration, making the 229703 suitable for clarifying protein solutions, enzyme preparations, and biological buffers where sample recovery is important.
Easy-to-Read Molded Graduations — Visual Volume Monitoring Easy-to-read molded graduations on bottle top filter. Molded graduation markings on the bottle top filter funnel allow real-time visual monitoring of filtration progress across the full 500mL volume.
Bold Membrane Identification Printing — 0.45µm Clearly Marked Housings feature boldly printed membrane material and pore size for easy identification. The 0.45µm pore size is boldly printed on the filter housing — critical for preventing accidental use of the clarification filter in applications requiring 0.22µm sterile filtration.
Angled Hose Barb Adapter — Fits Three Tubing Sizes, Prevents Tipping Angled hose barb adapter fits three size hose diameters and prevents the filter from tipping. The angled barb accommodates 6mm, 9mm, and 12mm ID vacuum tubing without adapters and prevents the filter system from tipping during filtration.
Curved Bottle Design and Improved Filter Support Curved bottle design for easy handling. Improved filter support provides faster flow rates. The curved bottle profile provides ergonomic one-handed handling, while the improved filter support grid maintains membrane geometry under vacuum for sustained high flow rates throughout the full filtration volume.
Lot Number and Expiration Date on Every Bottle Top Printed lot number and expiration date on every bottle top. Full lot traceability supporting regulated laboratory environments and quality management documentation.
Compatible Replacement — Cross-Reference Guide
The CELLTREAT® 229703 is a direct compatible replacement for 500mL 0.45µm PES vacuum filter systems from several major manufacturers:
- Millipore® SCHVU05RE — Stericup 500mL 0.45µm PES filter system, sterile
- Thermo Fisher Nalgene™ 450-0045 — Nalgene Rapid-Flow 500mL 0.45µm PES filter, sterile
- VWR® 10040-442 — VWR 500mL 0.45µm PES bottle top filter system, sterile
Competitor brand names and catalog numbers are referenced for cross-referencing purposes only. Compatibility should be verified for your specific application and protocol.
Complete CELLTREAT® Filter System Family:
| Cat. # | Volume | Pore Size | Membrane Dia. | Sterile Filtration | Case Qty |
|---|---|---|---|---|---|
| 229701 | 150mL | 0.45µm | 50mm | No — clarification | 12 |
| 229702 | 150mL | 0.22µm | 50mm | Yes | 12 |
| 229703 | 500mL | 0.45µm | 90mm | No — clarification | 12 |
| 229707 | 500mL | 0.22µm | 75mm | Yes | 12 |
| 229708 | 1000mL | 0.22µm | 90mm | Yes | 12 |
Key Features
- Complete 500mL vacuum filter system — bottle top filter, solution bottle, and HDPE cap included
- 0.45µm PES membrane — particle removal and solution clarification
- ⚠️ 0.45µm does NOT provide sterile filtration — use 229707 (0.22µm, 500mL) for sterile applications
- Expanded 90mm membrane diameter — 44% more filtration area than previous membrane
- High flow rate with low protein binding PES membrane
- Improved filter support — sustained flow rates under vacuum
- Easy-to-read molded graduations on bottle top filter
- Bold printed membrane material and 0.45µm pore size — easy identification
- Curved bottle design — ergonomic handling
- Angled hose barb adapter — fits 6mm, 9mm, and 12mm ID tubing, prevents tipping
- Lot number and expiration date printed on every bottle top
- Polystyrene bottle and funnel / HDPE screw cap
- RNase-free and DNase-free — certified
- Non-pyrogenic
- Sterile — gamma irradiation
- Individually packaged
- Shelf life: 36 months
- 12 filter systems per case
Supported Applications HPLC mobile phase preparation and sample pre-filtration at 500mL scale, large-volume buffer and solution clarification, particle removal from biological solutions prior to analysis, pre-filtration before 0.22µm sterile filtration, removal of yeast and large particles from 500mL solutions, and any laboratory application requiring 0.45µm vacuum filtration of up to 500mL volume.
Technical Specifications
| Specification | Value |
|---|---|
| SKU / Catalog # | 229703 |
| Manufacturer | CELLTREAT Scientific Products |
| Volume | 500mL |
| Pore Size | 0.45µm |
| Sterile Filtration | No — clarification and particle removal only |
| Membrane Material | Polyethersulfone (PES) |
| Membrane Diameter | 90mm (44% more area than previous generation) |
| Housing Material | Polypropylene |
| Bottle Material | Polystyrene (graduated) |
| Cap Material | HDPE screw-on |
| Hose Barb | Angled — fits 6mm, 9mm, 12mm ID tubing |
| Protein Binding | Low |
| Sterility | Sterile — gamma irradiation |
| RNase-Free | Yes — certified |
| DNase-Free | Yes — certified |
| Non-Pyrogenic | Yes |
| Lot/Expiry Printing | Yes — on every bottle top |
| Packaging | Individually packaged |
| Shelf Life | 36 months |